717R Kit 1
£530.00
The TPI 717R Flue Gas Combustion Analyser is a state of the art, easy to use analyser designed not only to display and calculate the required readings from a flue but also to cover most of the other desirable parameters associated with appliance installation and maintenance.
Kit 1 contains all Standard Accessories and includes:
A740 Infrared Printer
In stock
Description
717R Kit 1 with Standard Accessories and includes:
A740 Infrared Printer
- TPI 717R Analyser
- H2 ready! EN50379 compliant
- Rubber Boot (A765)
- Soft Carrying Case (A768)
- Sampling Probe (c/w Type “K” Thermocouple)
- In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
- Battery Charger (A766)
- Mini In-Line Pump Protection Filter (c/w 5 spare filters)
- Exhaust Spigot Removable (A764)
- Battery Charger (A766) – 1 each
- Mini Pump Protection Filter Assembly (A763) – 1 each
- Exhaust Spigot Removable (A764) – 1 each
- Pressure Tubing (2 x 1 metres)
For full product details and Kit Options please visit the product page here 717R Flue Gas Analyser
Additional information
Weight | 3 kg |
---|---|
Dimensions | 46 × 30 × 19 cm |
Video
Details
- Combustion Efficiency Analyser: Measure O2, CO, and flue temperature. Calculate efficiency, excess air, CO2 & (CO/CO2) Ratio.
- CO Analyser: Measure carbon monoxide in ambient air.
- Differential Manometer: +/- 150 mBar (0.01 mBar resolution). Great for tightness/let by or burner pressure testing.
- Differential Thermometer: Dual input K-Type thermocouple thermometer measures differential temperatures. Ideal for measuring & recording flow & return temperatures.
- Six Year Warranty
All of the features of the 709R plus:
- Timed Let/By & Tightness Test
- Timed CO Build-Up Room Test
- Integrated Magnet
- Calibration Due Countdown on switch on
- Serial Number on Print-Outs
- Next Calibration Due Date on Print-Outs
Standards
The TPI 717R conforms to EN50379 and is suitable for engineers working with BS7967, the usage standard.
Serial Number & Next Cal Due Date are printed at the bottom of each print-out ensuring that you always know your readings have been taken with the correct in-calibration flue gas analyser giving you complete peace of mind.
HHIC: The Heating & Hotwater Industry Council made a recommendation that from April 2013 that the CO level & CO/CO2 (Ratio) reading in a flue is recorded when a boiler is commissioned and that this practise become mandatory from April 2014. Please click here for further details.
The recording of the CO level and Ratio reading will become a mandatory part of completing the Benchmark Form.
Combustion Performance Analysis (CPA1): From April 2012 it has been compulsory for all engineers to acquire CPA1 Assessment to prove their competency in using a Flue Gas Analyser. Please click here for complete details.
Specifications
Model 717R Specifications | ||
---|---|---|
Instrument | ||
Operating Temperature Range | 14°F to +122°F (-10°C to +50°C) | |
Battery / Batery Life | Rechargeable Ni-MH / > 6 Hours | |
Charger Input Voltage | 115V or 230V : 50/60 Hz AC | |
Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse |
|
Pressure Ranges | mbar, kPa & inH2O | |
Display | Backlit Graphic LCD | |
Data Storage | 50 sets of readings, multiple pages | |
Time and Date | 24 Hour Real Time Clock | |
Dimensions | 200mm x 90mm x 60mm | |
Weight | 500g | |
Casing | Rubber Boot as Standard | |
Switch Off | Failsafe | |
Exhaust | Safety Spigot | |
Conforms to | EN50379 |
Flue Temperature Probe | ||
---|---|---|
Construction | Pistol Grip with Stainless Steel Shaft | |
Hose Length | 2500mm | |
Insertion Length | 200mm | |
‘K’ Type Thermocouple Accuracy | +/- 0.3%, +/- 1˚C | |
Maximum Temperature | 800°C |
Gases | Range | Resolution | Accuracy | |
Oxygen | 0-25% | 0.1% | +/- 0.3% | |
Carbon Monoxide | 0-10,000 ppm | 1 ppm | <20ppm +/- 3 ppm >100ppm +/- 5% |
|
Carbon Dioxide (calculated) | 0-25% | 0.1% | +/- 0.3% | |
Combustion Efficiency | 0-100% | 0.1% |
Pressure Measurement | ||
---|---|---|
Selectable Ranges | mbar, kPa and inH2O | |
Range | – 150 mbar to + 150 mbar | |
Resolution | 0.01 mbar & 0.1 mbar | |
Accuracy | +/- 0.5% fsd |