126 Digital Multimeter
£47.00
Compact autoranging DMM with 0.3% DCV basic accuracy and 400mA AC/DC range.
In stock
Description
Compact autoranging DMM with 0.3% DCV basic accuracy and 400mA AC/DC range.
- 4,000 count display
- 0.3% DCV basic accuracy
- 0 to 600 ACV; max resolution 1mV
- 0 to 40MΩ; max resolution 0.1Ω
- Audible continuity
- Autoranging
- Min/Max
- Data Hold
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
Specifications
| Model 126 Specifications | ||
|---|---|---|
| DC Volts | Maximum Input: 1000V
Maximum Resolution: 0.1mV Accuracy: +/-0.3% |
|
| AC Volts | Maximum Input: 750V
Maximum Resolution: 0.001V Accuracy: +/-0.8% |
|
| DC Amps | Maximum Input: 400mA Maximum
Maximum Resolution: 0.1μA Accuracy: +/-0.8% |
|
| AC Amps | Maximum Input: 400mA Maximum
Maximum Resolution: 0.1μA Accuracy: +/-0.8% |
|
| Resistance (Ohms) | Maximum Input: 40MΩ
Maximum Resolution: 0.1mΩ Accuracy: +/-0.5% |
|
| Frequency | N/A | |
| Capacitance | N/A | |
| Inductance | N/A | |
| Temperature
(K-Type Thermocouple) |
N/A | |
| Continuity | Audible at less than 50Ω | |
| Diode | 3V at 30µA maximum output | |
| Duty Cycle | N/A | |
| True RMS Responding | No | |
| Conductance | No | |
| Pulse Width | No | |
| Data Hold | Yes | |
| Min/Max Record | Yes | |
| Time Stamp Logging | No | |
| Relative Mode | No | |
| Compare Mode | No | |
| RS-232 Output | No | |
| Process Loop Output | No | |
| Sleep Mode / Auto Off | No | |
| Protective Boot | Yes (standard) | |
| Display Type | 4000 count LCD | |
| Range Selection | Manual | |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) | |
| Storage Temperature | 14°F to 122°F (-10°C to 50°C) | |
| Humidity | 80% non-condensing | |
| Size | 6” x 3.1” x 1.2” (187mm x 86mm x 33mm) with boot | |
| Weight | 12oz (340g) with boot | |
| Battery Type | 1.5V “AA” Alkaline (2) | |
| Battery Life | 200hrs Typical | |
| OverInput Category | CAT III 600V | |
| Agency Approval | cULus 61010-1, IEC 61010-1 | |
| Warranty | 3 Years | |
Applications
Tech Tips
Category Ratings:
- Category I: Usually electronic equipment or equipment where measures have been taken to limit transient over voltages.
- Category II: Single phase loads like appliance personal computers, television sets, and other household loads. Outlets located more than 30 feet froma CAT III source or more than 60 feet from a CAT IV source.
- Category III: Distribution level fixed installations like distribution panel devices, short branch and feeder circuits, three phase loads, and single phase commercial lighting.
- Category IV: Equipment and lines located on the power line side of a service panel or where a low voltage connection is made to utility power