153 Digital Multimeter
£65.00
Full size, autoranging, easy to read, 0.3% DCV basic accuracy DMM; 1,000 DC volts and 750 AC volts.
In stock
Description
Full size, autoranging, easy to read, 0.3% DCV basic accuracy DMM; 1,000 DC volts and 750 AC volts.
- 0.3% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 40MΩ; max resolution 0.1Ω
- AC/DC amps to 10; max resolution 0.1uA
- Autoranging
- Min/Max
- Data Hold
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
Specifications
Model 153 Specifications | ||
---|---|---|
DC Volts | Maximum Input: 1000V
Maximum Resolution: 0.1mV Accuracy: +/-0.3% |
|
AC Volts | Maximum Input: 750V
Maximum Resolution: 0.001V Accuracy: +/-0.8% |
|
DC Amps | Maximum Input: 10A
Maximum Resolution: 0.1μA Accuracy: +/-0.5% |
|
AC Amps | Maximum Input: 10A
Maximum Resolution: 0.1μA Accuracy: +/-0.8% |
|
Resistance (Ohms) | Maximum Input: 40MΩ
Maximum Resolution: 0.1mΩ Accuracy: +/-0.5% |
|
Frequency | N/A | |
Capacitance | N/A | |
Inductance | N/A | |
Temperature
(K-Type Thermocouple) |
N/A | |
Continuity | Audible at less than 50Ω | |
Diode | 3V at 30µA maximum output | |
Duty Cycle | N/A | |
True RMS Responding | No | |
Conductance | No | |
Pulse Width | No | |
Data Hold | Yes | |
Min/Max Record | Yes | |
Time Stamp Logging | No | |
Relative Mode | No | |
Compare Mode | No | |
RS-232 Output | No | |
Process Loop Output | No | |
Sleep Mode / Auto Off | Yes | |
Protective Boot | Yes (standard) | |
Display Type | 4000 count LCD | |
Range Selection | Auto/Manual | |
Operating Temperature | 32°F to 104°F (0°C to 40°C) | |
Storage Temperature | 14°F to 122°F (-10°C to 50°C) | |
Humidity | 80% non-condensing | |
Size | 6” x 3.1” x 1.2” (187mm x 86mm x 33mm) with boot | |
Weight | 12oz (340g) with boot | |
Battery Type | 9V | |
Battery Life | 500hrs Typical | |
OverInput Category | CAT III 600V | |
Agency Approval | cULus 61010-1, IEC 61010-1 | |
Warranty | Limited Lifetime |
Applications
Tech Tips
Category Ratings:
- Category I: Usually electronic equipment or equipment where measures have been taken to limit transient over voltages.
- Category II: Single phase loads like appliance personal computers, television sets, and other household loads. Outlets located more than 30 feet froma CAT III source or more than 60 feet from a CAT IV source.
- Category III: Distribution level fixed installations like distribution panel devices, short branch and feeder circuits, three phase loads, and single phase commercial lighting.
- Category IV: Equipment and lines located on the power line side of a service panel or where a low voltage connection is made to utility power