skip to Main Content

DC711 Flue Gas Analyser Kit 1

£695.00

DC711 Flue Gas Analyser. Designed to meet the needs of the busiest Gas Heating Engineer and Installer. Kit includes DC711 Analyser, A741BT Printer, Probe & Charger in Padded Carry Case. *NOTE: TPI View app connectivity requires either View-Up upgrade or purchase of DC711-View 1 Kit.

In stock

Description

The Best of Both Worlds.

  • Easy to Use, Durable & Affordable!
  • Domestic or Commercial
  • Upgradeable to include NOx sensor
  • Multiple Fuel Options
  • Hold, Save, Print & Send
  • Clear, Easy to Read Screen
  • Easy to Navigate Menu System
  • Pressure & Tightness Test feature
  • Differential Temperature for Flow & Return or Radiator Balancing
  • Upgrade to TPI View connectivity, NOW or in the FUTURE*

As DC711 Kit PLUS A741BT Wireless Printer

Overview

Features & Benefits

Kits & Upgrades

Essential Accessories

Specifications

DC711 Specifications
Instrument
Operating Temperature Range14°F to +122°F (-10°C to +50°C)
Battery / Battery LifeLi-ion 3.7V / > 6 Hours
Charger InputUSB “C” type
FuelsNatural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
Pressure Rangesmbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
DisplayBacklit Graphic LCD
Data Storage100 sets of readings (30 sets for CO Build Up), multiple pages
Time and Date24 Hour Real Time Clock
Dimensions7.28” (185mm) x 4.92” (125mm) x 2.56” (65mm)
Weight1.83lbs (830g)
Conforms toEN50379 : Parts 1-3
Flue Temperature Probe
ConstructionPistol Grip with Stainless Steel Shaft
Hose Length8.2’ (2500mm)
Insertion Length7.9” (200mm)
‘K’ Type Thermocouple Accuracy+/- 0.3% of fullscale, +/- 2°F (1°C)
Maximum Temperature1472°F (800°C)
GasesRangeResolutionAccuracy
Oxygen0-25%0.1%+/- 0.3%
Carbon Monoxide (low)0-10,000 ppm1 ppm(<100ppm) +/- 5 ppm
(>=100ppm) +/- 5%
Carbon Monoxide (high)*0-100,000 ppm0.001%>10,000ppm: +/- 10%
Nitric Oxide *0-5000ppm1 ppm+/- 5ppm (<100ppm)
+/- 5% (<1000ppm)
+/- 10% (>1000ppm)
Carbon Dioxide0-25%0.1%Calculated
CO/CO2 Ratio0-0.9990.001Calculated
Combustion Efficiency0-100%0.1%Calculated
* if fitted
Pressure Measurement
Selectable Rangesmbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
Range– 150 mbar to + 150 mbar
-15 kPa to + 15 kPa
-60 inH2O to 60 inH2O
Resolution0.001 mbar (0~9.999 mbar)
0.01 mbar (10.00~149.99 mbar)
Accuracy+/- 0.5 mbar FSD
Temperature Measurement
Input TypeK-Type thermocouple
Range-58°F to 1832°F (-50°C to 1000°C)*
Resolution1°F (1°C)
Accuracy+/- (0.3% of rdg + 2°F) or +/- (0.3% of rdg + 1°C)

You may also like…